ebsite of McScience Inc. K3000 Solar Cell I-V Test System. K3100 Solar Cell IPCE Measurement System. K3300 Solar Cell Imaging System. K3400 PV Response Measurement System. K5300 PV Module Imaging System. K5500 PV Module Inspection System. K5700 PV Module Light Soaking System. M6000 OLED Lifetime Test System. M6100 OLED I-V-L Test System. M7000 FPD Optical Test System. T3000 FPD Optical Test System. T4000 Organic Semiconductor Parameter Test System. T5000 TFT Parameter Test System. SimuLight™. Xe Series. New & Report. Product Review. Product of Solar Cell, Display, Battery, OLED test system. Contact Us, Company information, Global Partnership. BSYH Electronics Science & Technology Co., LTD. Advanced Optek Co., Ltd. Aseptec Sdn Bhd. Edge Tech Scientific PVT. LTd. Teknotip Analitik Sistemler Ltd. Sti.lar Simulator. I-V Test. Solar Efficiency. Class AAA Solar Simulator. Fast I-V Characterization. Custom-desined Test

Hardware

Channel Max. 256ch
Configuration 1Ch per 1Subrack
Test Pack Type 8-cell Serial
Operation Mode CC, CV, CP, CC/CV, OCV, Rest, Pulse, Pattern
Voltage Programming Range 5 ~ 40V
Voltage Programming Accuracy Under FS ±0.1%
Charge Current Programming Range 20A, 2A (2Range)
Charge Current Programming Accuracy FS ±0.1%
Discharge Current Programming Range 100A (1Range)
Discharge Current Programming Accuracy FS ±0.1%
Control Interval 100mSec
Data Acquisition Interval 10mSec
Data Storage Interval 10mSec
Cell Balancing Channel 8Ch
Cell Balancing Resolution 1mV, 1mA
Cell Balancing Accuracy Balancing Voltage: <10mV
Temperature Measurement RTD 1Ch
Protect Option Over Voltage / Over Current / Over Temperature / Circuit Over Temperature / EMG S/W

Software

Cycle Condition Management Input and manage detailed conditions according to production process conditions
Up to 100 steps available
Repeat a given step for a given number of times
Pulse Discharge Function
Live Monitoring ?Live monitoring of data of each cell in the current process
(Voltage, current, capacity, time, internal resistance, Watt Hr, temperature)
Start/Pause/Restart/Stop job check communication status and error log)
Data Management ?Report function of measurement data (per tray, per cell)
Excel, Text file conversion (print function)
Cell Protection ?Detecting set voltage, current abnormality or less during charging/discharging -> Channel stop
Full channel stop when circuit overheated
Data Recovery ?Recover lost data (within 7days)
Automatic Stop ?Automatic stop when voltage/ current suddenly changes when rated voltage / current is exceeded
Emergency Stop ?Pause work in progress in case of emergency stop
The process will re-start after releasing select progress/restart/stop