Product Model  M6000PLUS OLED Lifetime Test System
System Configuration  Main Rack System, M600PRO OLED Lifetime Tester, PD Jig, Signal Cables, PC, S/W
Lifetime Test Channel  32ch/64ch/96ch
Source Mode  CV, CC, CL, PV, PC, PCV
Voltage Source Range  -20V ~ +20V
Measurement Accuracy  ±0.05% + 10mV (Full Scale)
Current Type  2 Range Shunt Type (Manual)
Range  Range 1: -1mA ~ +1mA / Range 2: -10mA ~ +10mA
Source Accuracy  ±0.05% + 2uA (Full Scale)
Measurement Range  Range 1: -1mA ~ +1mA / Range 2: -10mA ~ +10mA
Measurement Accuracy  ±0.05% + 1uA (Full Scale)
PhotoCurrent Type  3 Range ZRA Type (Manual)
Measurement Range  Range 1: 0 ~ 10uA / Range 2: 0 ~ 100uA / Range 3: 0 ~ 1mA
Measurement Accuracy  Range 1: ±0.05% + 5nA (Full Scale) / Range 2: ±0.01% + 5nA (Full Scale)  Range 3: ±0.01% + 5nA (Full Scale)
DAC Resolution  16bit
ADC Resolution  16bit
Pulse Operation  Independent Channel Control
Frequency  10 ~ 256Hz, 1Hz Step
Duty  1 ~ 99%, 1% Step
Measurement Interval  Min. 100msec
I-V-L Test Test Mode  Voltage Sweep, Current & Photocurrent Measurement
Connection  2 or 4 Probe
Voltage Sweep  Range: -20V ~ +20V / Step: 10mV
Current Measurement  Range: -1mA ~ 1mA or -10mA ~ 10mA (Manual Selection) / Accuracy: ±0.1% + 2uA (Full Scale)
Photocurrent Measurement  Range: 0 ~ 10uA or 0 ~ 100uA or 0 ~ 1mA (Manual Selection) / Accuracy: ±0.05% + 5nA (Full Scale)
Sweep Point  Max. 100 point
Step Duration  Min. 100msec

TOP